| C1–C2 environmental reference | Discolouration or isolated surface oxidation; no fixed confidence threshold. | Image quality, material/coating, exposure and site context. | Check ISO 8501-1 visual reference and system selection against owner specifications. | Prompt evidence completion and human review; do not automatically defer inspection. | Not calculated; requires approved scope, effective cost version, and human review. |
|---|
| C3 environmental reference | Coating disbondment, blistering or boundary change; verify lighting and occlusion. | Comparable imagery, coating history and field check. | ISO 12944 is a candidate coating-system and owner-specification review reference only. | Create a human-review prompt; do not automatically create a CMMS work order. | Not calculated; requires approved scope, effective cost version, and human review. |
|---|
| C4 environmental reference | More widespread visible rust; imaging cannot estimate metal loss or structural thinning. | Location, material, NDT thickness and site procedure. | Qualified personnel check current ISO 1461, duplex, or other applicable requirements. | Prompt field/NDT review; no automatic UAV dispatch, restriction, or tasking. | Not calculated; requires approved scope, effective cost version, and human review. |
|---|
| C5–CX environmental reference | High-severity visual indications; no image-only failure or load determination. | Field measurement, hazard assessment, owner procedure and engineering review. | No universal replacement, cathodic-protection or alloy instruction is issued. | Provide a human escalation prompt; no automatic alarm, shutdown, or isolation. | Not calculated; requires approved scope, effective cost version, and human review. |
|---|
| Pitting / perforation cue | Local cavity, shadow or edge anomaly is a viewing cue, not a perforation finding. | Same-point location, targeted NDT, medium and component context. | Candidate local treatment requires project repair specification and engineering review. | Prompt targeted inspection; do not automatically create repair or CP work. | Not calculated; requires approved scope, effective cost version, and human review. |
|---|
| CUI cue | Thermal or insulation-area anomaly is a cue, not a CUI diagnosis. | Insulation field check, temperature conditions, NDT and documented method. | AMPP SP0198 may inform systematic review; personnel confirm applicability. | Prompt owner-procedure review; do not automatically issue confined-space or gas-monitoring permits. | Not calculated; requires approved scope, effective cost version, and human review. |
|---|